METTLER TOLEDO Weigh Module Systems Handbook
(12/99)
5-18
Piping Installation
This section shows ways to install piping in order to avoid deflection problems.
The greater the distance between the tank and the first pipe support, the more
flexible the piping connection will be (see Figure 5-21a). Use a section of flexible
hose so that the pipe does not exert unwanted forces when the tank deflects
(Figure 5-21b).
Figure 5-21a: Distance Between Tank and Pipe Support Figure 5-21b: Piping with Length of Flexible Hose
A 90-degree bend in a horizontal run of pipe will make the piping more flexible
(see Figure 5-22).
Figure 5-22: Horizontal Piping with 90-Degree Bend
Flexible Hose
Maximize
Distance
Vue de la page 59