Chapter 5: General Installation Guidelines
Applying Force to Load Cells
(12/99)
5-3
Eccentric Loading
Eccentric loading occurs when a vertical force is applied to a load cell at a point
other than its center line (see Figure 5-4). This problem can be caused by thermal
expansion and contraction or by poorly designed mounting hardware. You can
avoid eccentric loading problems by using a weigh module system that will
compensate for expansion and contraction.
Figure 5-4: Eccentric Loading
Side and End Loading
Side and end loading occur when horizontal forces are applied to the side or end
of a load cell (see Figure 5-5). They can be caused by thermal expansion and
contraction, by misalignment, or by vessel movement due to dynamic loading.
Side and end forces can affect the linearity and hysteresis of the scale. For static
loading applications, use a weigh module system that compensates for thermal
movement. For dynamic loading applications, use a weigh module system with a
self-aligning load pin suspension.
Figure 5-5: Side and End Forces Applied to a Load Cell