METTLER TOLEDO Weigh Module Systems Handbook
(12/99)14-22
Load Cell Wiring
Function Color for Model
743 (45K only)
Color for Model
777 (5-100 kg)
Color for Model
713
Color for All Other
Load Cells
+Excitation White Blue Red Green
+Sense -- Green* -- --
+Signal Green White Green White
Shield Yellow Yellow Yellow Yellow
-Signal Black Red White Red
-Sense -- Gray* -- --
-Excitation Blue Black Black Black
* For Model 777 load cells, connect the +Sense wire to the +Excitation terminal and the -Sense wire to the
-Excitation terminal.
Table 14-12: IDNet Junction Box Wiring Codes
Jumper Status Description
W1 Closed (ON) Matching the gain at 2 mV/V load cells
W2 Closed (ON) No external sensing (-Sense)
W3 Closed (ON) No external sensing (+Sense)
W4 Closed (ON) Internal reference voltage = 3.5 volts
W5 Open (OFF) Excitation voltage for load cells = 4.0 volts
W6 Closed (ON) Internal supply voltage = 7.1 volts
W7 2-3 Protocol IDNet
W8 1-2 Interface 20 mA
W9 Open (OFF) Supply voltage IDNet
SA1 Closed (ON) Trim potentiometers circuit disabled
Table 14-13: IDNet Junction Box Default Factory Setting
Note: For 2 mV/V load cells, jumpers
W1, W2, W3, and W4 must be ON
(shorting the pins).