Mettler Toledo MT Guide de l'utilisateur Page 61

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 129
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 60
IND780 User’s Guide
5. Press the OK softkey
to load the selected record from the list and return to
the weighing operation screen, or Press the EXIT softkey
to return without
loading the record.
Comparators
Comparators are simple targets, twenty of which can be configured in setup. They
are controlled either by coincidence or by comparison with a target or range. The
source for comparison can be the Gross Weight, Displayed Weight, Rate or
assigned by a custom TaskExpert application. When assigned to the home screen,
the Comparator softkey
permits direct access to the Comparators for the
current selected scale. As seen in Figure 2-23, this screen displays each
Comparator’s ID, Description, Limit, Units, High Limit (if applicable) and Active
operator, provided that they have been configured in setup.
To make changes to a Comparator directly from the home screen, if the
Comparator ID is known, press the ID number and then the Comparator softkey
. If the ID is not known, press the Comparator softkey , use the UP/DOWN
keys to select the desired Comparator from the list, and press the Edit softkey
.
Only the limit value/s can be edited. To edit parameters other than limits, the
Comparator configuration screen must be accessed in setup.
Figure 2-23: Comparators List for Scale 2
When the Active operator value is <, <=, =, < >, >= or >, the selected source is
compared to a target weight. When the Active value is within (>_ _<) or outside
(_< >_) a range, the selected source is compared to a range defined by the Limit
and High Limit values.
Using Comparators
To use a Comparator, it must be assigned to a discrete output. Comparators are
not associated with SmartTrac.
Target Value Comparators
In this case, the output will be triggered depending on the Active setting. For
example, if the Active operator is < (less than) and the Limit is 1000 kg, the
output will turn OFF when the measured value reaches 1000 kg.
2-36
Vue de la page 60
1 2 ... 56 57 58 59 60 61 62 63 64 65 66 ... 128 129