WARNING!
THE DISCRETE OUTPUTS OF THE IND780 TERMINAL WILL BE MANUALLY
ENABLED DURING THIS TEST. REMOVE OUTPUT CONTROL POWER SO
EXTERNAL EQUIPMENT WILL NOT BE ENERGIZED BY MISTAKE. EXERCISE
CARE WHEN MAKING CHECKS, TESTS AND ADJUSTMENTS THAT MUST BE
MADE WITH POWER ON. FAILING TO OBSERVE THESE PRECAUTIONS CAN
RESULT IN BODILY HARM AND/OR PROPERTY DAMAGE.
When viewing the test screen, the input status will be shown at the top of the
display and the output status will be shown at the bottom of the display. Focus is
shown on Output #1 first.
Focus can be moved to any of the other outputs by using the RIGHT and LEFT
navigation keys on the front panel, or pressing ENTER.
Note that when the Discrete I/O Test screen is exited, all outputs will be turned off
again.
Network Test—Enables testing of the Ethernet programming/hardware/firmware
in the terminal. Figure 3-29 shows the result of running a network test.
Figure 3-29: Network Test Screen
The following tests are run during this diagnostic process:
TCP/IP Stack
This Terminal
Gateway Address
Email Server
Each step will indicate “Testing” during the test then indicate a Pass or Timeout
status. If the status is shown as Timeout, it indicates that the IP address or
gateway address has not been programmed in the terminal. Refer to the
Communication and Network section of Chapter 3.0, Configuration, for information
on entering the IP and gateway addresses.