3.2 I/O port commands for interface 103 digital I/O
Input/output buffer of the I/O port
Reading of the inputs or setting of the outputs is effected via an input or output buffer. The input and output
ports must be switched in the master mode to EXTERN for this.
Both buffers are separate application blocks.
Reading inputs
Application For reading the inputs of the I/O port.
Command format {A|R|107|ç[ƒ}
Action After receipt of the "AR" command, the terminal sends the 6 input states of the I/O port.
Response format {A|B|6 input bits|ç[ƒ}
Remarks Input states:
Logic "0" = no current (contact open)
Logic "1" = current flow (contact closed)
With the ID1 Plus only inputs 1 and 2 are used.
6
1
➝
Input
buffer 107
Output
buffer 106
Interface 103
e.g.
SPC
Interface 101
Interface 102
Interface 104
ID1 Plus
5
5
4
3
6
1
2
Front view
2.3 Technical data Interface 104 RS422/RS485
Interface 104 is a retrofittable interface for the ID1 Plus weighing terminal which can be operated either as an
RS422 (4-wire full duplex) or RS485 (2-wire half duplex). In both cases one peripheral device can be
attached to the weighing terminal.
Factory setting: RS422
Interface mode bidirectional differential voltage interface
Max. operating length 1200 m
Transmission rate 150 - 19200 baud
Galvanic separation optocoupler
Connector
6-pin round connector, socket
Appropriate male connector: order No. 204 866
Pin assignment
RS422 RS485
Pin 1 GND GND
Pin 2 +5 V (max. 100 mA) +5 V (max. 100 mA)
Pin 3 TXD + TXD + / RXD +
Pin 4 TXD – TXD – / RXD –
Pin 5 RXD – not assigned
Pin 6 RXD + not assigned
Vue de la page 0
1 2 3 4 5 6 7 8

Résumé du contenu

Page 1 - ID1 Plus

83.2 I/O port commands for interface 103 digital I/OInput/output buffer of the I/O portReading of the inputs or setting of the outputs is effected via

Page 2 - 3 Command set

61white2brown3green4yellow5pink6grey6-pin connectoropen endST7ST2ST3ST4ST5ST6ST1on/offon/offCableCable with 6-pin connector and open end, length 3 m.

Page 3 - 2 Technical data

103.3 Target value entry for LED analog displayApplication For entering the target value in plus/minus weighing.Command format In weighing-in:{A[W|0[2

Page 4 - Front view

4Connector7-pin circular connector, femalePins 1 and 2 receiving loop (scale)Pins 4 and 5 transmitting loop (scale)Pin 7 protective groundCablesCables

Page 5 - 1 Installation instructions

124.2 Response formats in readingNumber Response format002 {A|B|_|I|T|1|+|-|0|-|0|X|X|X|ç[ƒ} xxx = current version number003 {A|B|_|STX|ç[ƒ}004 {A|B|_

Page 6 - 4 Application blocks

2• Plug interface connector into main board and secure.• Plug weighing platform connector into main board.• Pull out power cable and tighten heavy gau

Page 7 - METTLER TOLEDO ID1 Plus

Mettler-Toledo (Albstadt) GmbH, D-72458 Albstadt, Germany, Tel. (0 74 31) 14-0, Fax (0 74 31) 14-232A Mettler-Toledo Ges.m.b.H., 1100 Wien, Tel. (01)

Page 8 - Contents

1ContentsPage1 Installation instructions 12 Technical data 2.1 Technical data of interface 101 CL 20 mA 32.2 Technical data of interface 102 RS232 42.

Commentaires sur ces manuels

Pas de commentaire