48
Interface description
User manual 22013194B 05/08
5 Interface description
5.1 SICS interface commands
The terminal IND445 supports the command set MT-SICS (METTLER TOLEDO Stand-
ard Interface Command Set). With SICS commands, it is possible to configure, query
and operate the terminal from a PC. SICS commands are divided up into various lev-
els.
5.1.1 Available SICS commands
In the case of Levels 0 and 1, these are commands which, if implemented, will
function identically with all METTLER TOLEDO scales or weighing terminals.
In addition there are also further interface commands which apply either to the entire
product series or to the particular application level. This and further information on the
MT-SICS command set may be found in the MT-SICS Manual (Order Number 22 011
459 or at www.mt.com) or be obtained by request from your METTLER TOLEDO
customer service representative.
Command Meaning
LEVEL 0 @ Reset the scale
I0 Inquiry of all available SICS commands
I1 Inquiry of SICS level and SICS versions
I2 Inquiry of scale data
I3 Inquiry of scale software version
I4 Inquiry of serial number
I6 Inquiry of weighing parameters
S Send stable weight value
SI Send weight value immediately
SIR Send weight value repeatedly
Z Zero the scale
ZI Zero immediately
LEVEL 1 D Write text into display
DW Weight display
K Keyboard check
SR Send and repeat stable weight value
TTare
TA Tare value
TAC Clear tare
TI Tare immediately